SDI-12 measurements

The SoilVue 10 responds to the SDI-12 commands shown in SoilVue 10 SDI-12 commands. Because of the delays the M! command requires, Campbell Scientific recommends measurement scans of at least 10 seconds per sensor. For instance, the recommended scan rate for a 0.5‑m probe with six sensors is at least 60 seconds. A C! command does not require the data logger to pause its operation until the values are ready.

SoilVue 10 SDI-12 commands

SDI-12 command2

Values returned (units) or function

Units

aM!
  • 1. Volumetric water content, 5 cm (m3/m3)
  • 2. Volumetric water content, 10 cm (m3/m3)
  • 3. Volumetric water content, 20 cm (m3/m3)
  • 4. Volumetric water content, 30 cm (m3/m3)
  • 5. Volumetric water content, 40 cm (m3/m3)
  • 6. Volumetric water content, 50 cm (m3/m3)
  • 7. Volumetric water content, 60 cm (m3/m3)1

    8. Volumetric water content, 75 cm (m3/m3)1

    9. Volumetric water content, 100 cm (m3/m3)1

     
     
     
     
     
     
     
     
     
    aM1! or aC1!
    1. Volumetric water content, 5 cm (m3/m3)
  • 2. Relative permittivity (ɛ), 5 cm
  • 3. Temperature, 5 cm (°C)
  • 4. Bulk electrical conductivity, 5 cm (dS/m )
  • m3/m3
     
     
     
    aM2! or aC2!
    1. Volumetric water content, 10 cm (m3/m3)
  • 2. Relative permittivity (ɛ), 10 cm
  • 3. Temperature, 10 cm (°C)
  • 4. Bulk electrical conductivity, 10 cm (dS/m)
  •  
     
     
     
    aM3! or aC3!
    1. Volumetric water content, 20 cm (m3/m3)
  • 2. Relative permittivity (ɛ) 20 cm
  • 3. Temperature, 20 cm (°C)
  • 4. Bulk electrical conductivity, 20 cm (dS/m )
  •  
     
     
     
    aM4! or aC4!
    1. Volumetric water content, 30 cm (m3/m3)
    2. Relative permittivity (ɛ), 30 cm
  • 3. Temperature, 30 cm (°C)
  • 4. Bulk electrical conductivity, 30 cm (dS/m)
  •  
     
     
     
    aM5! or aC5!
    1. Volumetric water content, 40 cm (m3/m3)
  • 2. Relative permittivity (ɛ), 40 cm
  • 3. Temperature, 40 cm (°C)
  • 4. Bulk electrical conductivity, 40 cm (dS/m)
  •  
     
     
     
    aM6! or aC6!
    1. Volumetric water content, 50 cm
  • 2. Relative permittivity (ɛ), 50 cm
  • 3. Temperature, 50 cm
  • 4. Bulk electrical conductivity, 50 cm
  • m3/m3
     
    °C
    dS/m
    aM7! or aC7!1
    1. Volumetric water content, 60 cm
  • 2. Relative permittivity (ɛ), 60 cm
  • 3. Temperature, 60 cm
  • 4. Bulk electrical conductivity, 60 cm
  • m3/m3
     
    °C
    dS/m
    aM8! or aC8!1
    1. Volumetric water content, 75 cm
  • 2. Relative permittivity (ɛ), 75 cm
  • 3. Temperature, 75 cm
  • 4. Bulk electrical conductivity, 75 cm
  • m3/m3
     
    °C
    dS/m
    aM9! or aC9!1
    1. Volumetric water content, 100 cm
  • 2. Relative permittivity (ɛ), 100 cm
  • 3. Temperature, 100 cm
  • 4. Bulk electrical conductivity, 100 cm
  • m3/m3
     
    °C
    dS/m
    aC!
    1. Volumetric water content, 5 cm
    2. Relative permittivity (ɛ), 5 cm
    3. Temperature, 5 cm
    4. Bulk electrical conductivity, 5 cm
    5. Volumetric water content, 10 cm
    6. Relative permittivity (ɛ), 10 cm
    7. Temperature, 10 cm
    8. Bulk electrical conductivity, 10 cm
    9. Volumetric water content, 20 cm
    10. Relative permittivity (ɛ), 20 cm
    11. Temperature, 20 cm
    12. Bulk electrical conductivity, 20 cm
    13. Volumetric water content, 30 cm
    14. Relative permittivity (ɛ), 30 cm
    15. Temperature, 30 cm
    16. Bulk electrical conductivity, 30 cm
    17. Volumetric water content, 40 cm
    18. Relative permittivity (ɛ), 40 cm
    19. Temperature, 40 cm
    20. Bulk electrical conductivity, 40 cm
    21. Volumetric water content, 50 cm
    22. Relative permittivity (ɛ), 50 cm
    23. Temperature, 50 cm
    24. Bulk electrical conductivity, 50 cm
    25. Volumetric water content, 60 cm1
    26. Relative permittivity (ɛ), 60 cm1
    27. Temperature, 60 cm1
    28. Bulk electrical conductivity, 60 cm1
    29. Volumetric water content, 75 cm1
    30. Relative permittivity (ɛ), 75 cm1

     

     

    31. Temperature, 75 cm1
    32. Bulk electrical conductivity, 75 cm1
    33. Volumetric water content, 100 cm1
    34. Relative permittivity (ɛ), 100 cm1
    35. Temperature, 100 cm1
    36. Bulk electrical conductivity, 100 cm1
    m3/m3
     
    °C
    dS/m
    m3/m3
     
    °C
    dS/m
    m3/m3
     
    °C
    dS/m
    m3/m3
     
    °C
    dS/m
    m3/m3
     
    °C
    dS/m
    m3/m3
     
    °C
    dS/m
    m3/m3
     
    °C 
    dS/m
    m3/m3
     

     

     

    °C
    dS/m
    m3/m3
     
    °C
    dS/m

    aXLOADOS rrrrrCPU: OSname!

    where,

    rrrrr= baud rate

    OSname = OS name

    Sends the new OS to the sensor; refer to Updating the operating system using the XLOADOS SDI-12 instruction  
    ?! Returns the SDI-12 address  

    1 Applies to the 1.0-meter probe only.

    2 a is the SDI-12 address. In the SDI12Recorder() CRBasic instruction, the command parameter does not include the SDI-12 address because the address is a separate parameter.

    NOTE: