ComPort_Serial_In (Communications Port Serial In)
The COM port that will be used by the instruction. Right-click to display a list.
Alphanumeric | Description |
---|---|
ComRS232 | RS232 port of the datalogger |
ComMe | Datalogger's CS I/O port;modem enabled |
Com310 | Datalogger's CS I/O port; Com310 modem |
Com320 | Datalogger's CS I/O port; Com320 modem |
ComSDC7 | Datalogger's CS I/O port; SDC7 |
ComSDC8 | Datalogger's CS I/O port; SDC8 |
ComSDC10 | Datalogger's CS I/O port; SDC10 |
ComSDC11 | Datalogger's CS I/O port; SDC11 |
ComC1 | Datalogger's control ports 1 (TX) & 2 (RX) |
ComC3 | Datalogger's control ports 3 (TX) & 4 (RX) |
ComC5 | Datalogger's control ports 5 (TX) & 6 (RX) |
ComC7 | Datalogger's control ports 7 (TX) & 8 (RX) |
Type: Constant. For all instructions except SerialOpen, this parameter can also be a variable. However, if a variable is used, the port must be opened previously by SerialOpen (Open Communication Port)