SerialClose (Close Communication Port)

The SerialClose function is used to close a communications port that was previously opened by the SerialOpen function.

Syntax

SerialClose ( ComPort )

Remarks

This function returns True (-1) if the port was opened or False (0) if it was already closed.

Note that when executed, SerialClose will drop the DTR line on ComRS232 or the ME (modem enable) line on ComME.

This instruction can also be used along with other serial instructions to set up and control the SDM-SIO1A or SDM-SIO4A or SDM-SIO2R.

NOTE: This instruction runs sequentially from the processing task sequencer, regardless of whether the datalogger is in pipeline or sequential mode.

Parameter

ComPort (Communication Port)

The communication port that will be used by the instruction. Right-click to display a list.

Alphanumeric Description
ComRS232 RS232 port of the datalogger
ComME Datalogger's CS I/O port; modem enabled
Com310 Datalogger's CS I/O port; COM310 modem
Com320 Datalogger's CS I/O port; COM320 modem
ComSDC7 Datalogger's CS I/O port; SDC 7
ComSDC8 Datalogger's CS I/O port; SDC 8
ComSDC10 Datalogger's CS I/O port; SDC10
ComSDC11 Datalogger's CS I/O port; SDC 11
ComC1 Datalogger's control ports 1 (TX) & 2 (RX)
ComC3 Datalogger's control ports 3 (TX) & 4 (RX)
ComC5 Datalogger's control ports 5 (TX) & 6 (RX)
ComC7 Datalogger's control ports 7 (TX) & 8 (RX)

SerialOpen, SerialClose, SerialOut, and SerialOutBlock also support output via SDE pin enabled or any SDC address by using extended ComPorts. Valid extended ComPorts are &H1F through &Hff (31..255, SDC address including mode bits. Note, however, that 31 is SDE pin enabled and 32 through 47 are used to address the SDM-SIO1A). When an extended ComPort is used, the output instructions will turn on SDE or address the CS I/O port with the specified SDC address, delay the amount of time specified by TXDelay, output asynchronously at the specified baud rate in the SerialOpen() instruction, delay the amount of time specified by TXDelay, then reset the CS I/O port.

NOTE: The Argos and GOES satellite extended ComPort address is &H41 (65). To specify an SDC address, the most significant bit is the address; e.g., SDC 7 would be &H70 (112).

NOTE: When using the ComME ComPort with non-PakBus protocols (PPP, Modbus, DNP3, or generic serial applications), incoming characters can be corrupted by concurrent use of the CS I/O port for SDC communication (e.g., keyboard display).

Type: Constant. For all instructions except SerialOpen, this parameter can also be a variable.