Terminal master

Use the Terminal master command from a terminal mode to manually interrogate and enter settings in smart-sensors connected to a remote CR300 series. The Terminal master is useful for remotely accessing data logger terminal features such as SDI-12 and serial talk through modes for configuration and trouble shooting.

Using a terminal emulator enter the CR300 series terminal mode. For more information, see Using terminal mode

  1. Press Enter until the data logger responds with the prompt CR300 series>.

  2. Type T at the prompt and press Enter.

  3. In response, select the PakBus address of the remote data logger.

    Once the Terminal master option is entered, the terminal will present a new prompt, n*CR300>, where n is the remote CR300 series PakBus address.

  4. Now, the remote device terminal functions can be accessed.