Specifications

Wind speed specifications, Wind direction specifications, and Physical specifications provide the wind speed, wind direction, and physical specifications, respectively.

Wind speed specifications

 

05103
Wind Monitor

05108
Heavy Duty
Wind Monitor

05108-45
Heavy Duty
Wind Monitor‑
Alpine

05305
Wind Monitor-AQ

Range

0 to 100 m/s (0 to 224 mph)

0 to 50 m/s
(0 to 112 mph)

Accuracy

±0.3 m/s (±0.6 mph) or 1% of reading

±0.2 m/s
(±0.4 mph) or
1% of reading

Starting threshold

1.0 m/s (2.2 mph)

0.4 m/s (0.9 mph)

Distance constant (63% recovery)

2.7 m (8.9 ft)

2.1 m (6.9 ft)

Output

AC voltage (3 pulses per revolution); 1800 rpm (90 Hz) = 8.8 m/s (19.7 mph)

AC voltage (3 pulses per revolution); 1800 rpm (90 Hz) = 14.9 m/s (33.3 mph)

AC voltage (3 pulses per revolution); 1800 rpm (90 Hz) = 9.2 m/s (20.6 mph)

Resolution

(0.0980 m/s) / (scan rate in seconds) or (0.2192 mph) /
(scan rate in seconds)

(0.1666 m/s) / (scan rate in seconds) or (0.3726 mph) /
(scan rate in seconds)

(0.1024 m/s) / (scan rate in sec.) or (0.2290 mph) / (scan rate in sec.)

 

Wind direction specifications

 

05103
Wind Monitor

05108
Heavy Duty
Wind Monitor

05108-45
Heavy Duty
Wind Monitor-
Alpine

05305
Wind Monitor-AQ

Range

0° to 360° mechanical, 355° electrical (5° open)

Accuracy

±3°

Starting threshold

1.1 m/s (2.4 mph)

1.0 m/s (2.0 mph)

0.5 m/s (1.0 mph)

Distance constant (50% recovery)

1.3 m (4.3 ft)

1.2 m (3.9 ft)

Damping ratio

0.3

0.25

0.45

Damped natural wavelength

7.4 m (24.3 ft)

4.9 m (16.1 ft)

Undamped natural wavelength

7.2 m (23.6 ft)

4.4 m (14.4 ft)

Output

analog DC voltage from potentiometer—resistance 10 kΩ; linearity 0.25%;
life expectancy 50 million revolutions

Power

switched excitation voltage supplied by data logger

 

Physical specifications

 

05103
Wind Monitor

05108
Heavy Duty
Wind Monitor

05108‑45 Heavy Duty
Wind Monitor-Alpine

05305
Wind Monitor-AQ

Operating temperature range

–50 to +50 °C, assuming
non-riming conditions

–50 to +60 °C, assuming
non-riming conditions

‑50 to +50 °C, assuming
non-riming conditions

Overall height

37 cm (14.6 in)

40 cm (15.7 in)

38 cm (15 in)

Overall length

55 cm (21.7 in)

57 cm (22.4 in)

65 cm (25.6 in)

Propeller diameter

18 cm (7.1 in)

20 cm (7.9 in)

Mounting pipe description

34 mm (1.34 in) outer diameter; standard 1.0 in IPS schedule 40

Weight

1.5 kg (3.2 lb)

1 kg (2.2 lb)

1.1 kg (2.5 lb)