Terminal mode commands general
Summary of the terminal mode commands available provides a summary of the terminal mode commands.
To send commands that setup and control the SkyVue PRO, use the terminal interface, data logger, or terminal emulators built into many Campbell Scientific software products.
To load an operating system (OS), you need a terminal emulator with XMODEM protocol such as Tera Term.
Use the following settings:
Setting | RS-232/422/485 interface (default) | USB service port |
RS-232 |
||
Baud rate | 115200 | 115200 |
Data bits | 8 | 8 |
Parity | none | none |
Stop bits | 1 | 1 |
Flow control | none | none |
The baud rate of the SkyVue PRO must match the port setting baud rate in the terminal emulator. The SkyVue PRO should now be ready to accept commands.
Commands will always output all parameters on a new line after a CR LF (carriage return and line feed) and then the SkyVue PRO prompt CS135>. If you only want to see parameter values without changing them, then enter the command without parameters. If a particular parameter did not need changing, then the parameter can be replaced with a comma (,). Back space will abort the command.