Precautions

READ AND UNDERSTAND the Safety section at the back of this manual.

CAUTION:

This device uses considerably more power than the data logger, see Specifications. It may require a larger power supply, switching power with the data logger, or a combination of these to ensure the battery is not drained. See Controlling power to the RV50(X) for program examples of using switched 12V to control power to the RV50(X).

We strongly recommend changing the default RV50(X) ACEmanager password to prevent unauthorized access and the potential of malware infection. The password can be changed from the ACEmanager Admin tab.

WARNING:

Failure to set a strong password in the RV50(X) may result in misuse of the modem by malware or hackers. Significant data overage charges may apply.

To prevent unwanted data usage when using a public static IP, consider doing the following:

  • Limit open ports – Limit the number of configured ports that the RV50(X) is listening on. Open ports increase the chance of unwanted exploitation resulting in higher data usage and possible equipment misuse.

    The ACEManager template provided by Campbell Scientific limits these ports for you. Only the ports needed for communications with your data logger are opened. It is important to load the template prior to adding or deleting any additional ports.

  • Set Trusted IPs – The RV50(X) Trusted IP list limits devices that the RV50(X) will respond to. This requires entering the public IP address of each computer that will connect with or through the RV50(X). Each computer must have an unchanging public IP address set in ACEManager on the Security tab in the Trusted IPs - Inbound (Friends) field.

    CAUTION:

    Only set a Trusted IP address if you are familiar with the use of IP addresses. Consult your IT department or Campbell Scientific for assistance.

    NOTE:

    This setting does not affect outbound connections, only incoming connections.