RS-232 default settings

The following are factory-default data strings. RS-232 Default settings provides the RS-232 default settings.

MetSENS200

NODE, DIR, SPEED, CDIR, VOLT, STATUS, CHECK

┐Q,021,000.01,090,+05.1,0000,└ 36
 

Where,

┐: STX (Start of String character; ASCII value 2)

Q:

Node letter

021:

Wind direction
000.01: Wind speed

090

Corrected direction

+05.1

Supply voltage

0000

Status
ETX (End of String character; ASCII value 3)

36

Checksum (2 digit Hex Checksum sum figure calculated from the Exclusive OR of the bytes between, and not including, the STX and ETX characters)

MetSENS300

NODE, PRESS, RH, TEMP, DEWPOINT, VOLT, STATUS, CHECK

┐Q, 1015.3,041,+022.0,+008.5,+05.1,0000,└ 36
 

Where,

┐: STX (Start of String character; ASCII value 2)

Q:

Node letter

1015.3:

Pressure
041: Relative humidity
+022.0: Temperature
+008.5: Dewpoint

+05.1

Supply voltage

0000

Status
ETX (End of String character; ASCII value 3)
   

36

Checksum (2 digit Hex Checksum sum figure calculated from the Exclusive OR of the bytes between, and not including, the STX and ETX characters)

MetSENS500

NODE, DIR,SPEED, CDIR, PRESS, RH, TEMP, DEWPOINT, VOLT, STATUS, CHECK

┐Q,021,000.01,090,1015.3,041,+022.0,+008.5,+05.1,0004,└ 36
 

Where,

┐: STX (Start of String character; ASCII value 2)
Q: Node letter
021: Wind direction
000.01: Wind speed
090: Corrected direction
1015.3: Pressure
041: Relative humidity
+022.0: Temperature
+008.5: Dewpoint
+05.1: Supply voltage
0004: Status
└: ETX (End of String character; ASCII value 3)
36: Checksum (2 digit Hex Checksum sum figure calculated from the Exclusive OR of the bytes between, and not including, the STX and ETX characters)

MetSENS550/MetSENS600

NODE, DIR, SPEED, CDIR, PRESS, RH, TEMP, DEWPOINT, TOTAL PRECIP, PRECIP INTENSITY,
VOLT, STATUS, CHECK

┐Q,021,000.01,090,1015.3,041,+022.0,+008.5, 00000.200,000.200,+05.1,0004,└ 36
 

Where,

┐: STX (Start of String character; ASCII value 2)
Q: Node letter
021: Wind direction
000.01: Wind speed
090: Corrected direction
1015.3: Pressure
041: Relative humidity
+022.0: Temperature
0000.200: Precipitation total
000.200: Precipitation intensity
+05.1 Supply voltage
0004 Status
ETX (End of String character; ASCII value 3)
36 Checksum (2 digit Hex Checksum sum figure calculated from the Exclusive OR of the bytes between, and not including, the STX and ETX characters)

 

RS-232 Default settings

Setting

Setting

Setting

PROTOCOL: GILL AVGLONG: 101 SENSOR PRECIP: ON3
COMMS: RS232 SENSOR COMPASS: ON1 UNITS PRECIP: MM3
BAUD: 9600 COMPASSDECL: +000.01 POWER: 0
NODE: Q SENSOR TEMP: ON2 PUPMSG STATUS: ON
OUTFREQ: 1Hz UNITS TEMP: C2 PUPMSG REPORT: ON
MSGMODE: CONT SENSOR DEWPOINT: ON2 PUPMSG UNITS: ON
ASCTERM: CRLF UNITS DEWPOINT: C2 MODBUS: RTU
ECHO : ON SENSOR PRESS: ON2 MODADDR: 1
ALIGN: 01 UNITS PRESS: HPA2 DATABITS: 8
SENSOR WIND: ON1 HASL: +00000.002 STOPBITS: 1
UNITS WIND: MS1 HASTN: +00000.002 PARITY: NONE
NODIR: 0.001 SENSOR RH: ON2 MODTERM: 10
AVGSHORT: 601 UNITS RH: %2 MODICT: 1000

1 Not available for the MetSENS300

2 Not available for the MetSENS200

3 Only available for the MetSENS550 and MetSENS600