Wiring

NOTE:

Power down the system before wiring the CS451/CS456.

Wire color, function, and data logger connection for SDI-12 measurements provides data logger connections when using SDI-12 and Wire color, function, data logger connection, and RS-232 pin provides data logger connections when using RS-232.

Wire color, function, and data logger connection for SDI-12 measurements

Wire color

Wire function

Data logger connection

White

SDI-12 signal

C terminal or U configured for SDI-121

Clear

Shield

(analog ground)

Red

Power

12V, Battery+

Black

Power ground

G

Blue

Ground

G

Yellow

Ground

G

1 U terminals are automatically configured by the measurement instruction.

For the CR6 and CR1000X data loggers, triggering conflicts may occur when a companion terminal is used for a triggering instruction such as TimerInput(), PulseCount(), or WaitDigTrig(). For example, if the CS451 is connected to C3 on a CR1000X, C4 cannot be used in the TimerInput(), PulseCount(), or WaitDigTrig() instructions.

Wire color, function, data logger connection, and RS-232 pin

Wire color

CS451/CS456 function

Data logger connection

RS-232 9-pin

Red

+12vdc

12V, Battery+

 

Black

Power ground

G

 

White

RS-232 Tx (output)

Odd-numbered C terminal

Pin 2 Rx (input)

Blue

RS-232 Rx (input)

Even-numbered C terminal

Pin 3 Tx (output)

Yellow

Digital ground

G

Pin 5 GND

Clear

Shield GND

G