SIO4Cmd
Used to configure the SIO4. The commands are listed briefly below. See the SDM-SIO4 manual for details.
Code | Description |
---|---|
1 | Poll of available data |
2 | Get EPROM and memory signatures. |
3 | Flush all receive buffers. |
4 | Send data to datalogger. |
5 | Return number of watchdog errors, invalid command executed, and lithium battery voltage. |
6 | Flush transmit buffer. |
7 | Activate command line. |
8 | Poll TX buffers for data. |
9 | Flush converted data buffer. |
66 | Send single-byte data to datalogger. |
67 | Get return code |
320 | Send byte data to SDM-SIO4. |
321 | Execute command line command. |
1024 | Send string to SIO4. |
1025 | Transmit a byte. |
1026 | Serial port status. |
1027 | Manual handshake mode. |
2049 | Communication parameters. |
2054 | Set up receive filter. |
2304 | Transmit string and/or data to device (formatter/filter). |
2305 | Transmit bytes. |