SDICommand (SDI Command)
Used to specify the command strings that will be sent to the sensor. The command must be enclosed in quotes.
| Command | Description |
|---|---|
| ?! | Address query |
| aAb! | Change address (where a = current address and b = new address) |
| HB! | High-volume binary data |
| HA! | High-volume ASCII data |
| C! | Initiate concurrent measurements |
| CC! | Initiate concurrent measurements (with checksum) |
| I! | Send identification (destination variable must be formatted as a string) |
| M! | Initiate measurements |
| MC! | Initiate measurements (with checksum) |
| M1! - M9! | Additional measurement commands specified by the SDI-12 sensor |
| RC! | Continuous measurement (with checksum) |
| R0! - R9! | Continuous measurement commands |
| V! | Initiate verify sequence |
| X! | Extended commands (destination variable must be formatted as a string) |
If a check summed command fails, a NAN will be returned and the command will be retried.
Type: Constant or variable