Mode
Used to configure a bank of four ports when a Command code 86 through 90 is used (if any other Command Code is used, enter 0 for the Mode parameters). Mode is entered as a four digit parameter, where each parameter indicates the setting for a port. Ports are represented from the highest port number to the lowest, from left to right (e.g., 16 15 14 13; 12 11 10 9; 8 7 6 5; 4 3 2 1). There is a Mode for Ports 16 - 13, 12 - 9, 8 - 5, and 4 - 1. The valid codes are:
| Code | Description |
|---|---|
| 0 | Output logic low |
| 1 | Output logic high |
| 2 | Input digital, no debounce filter |
| 3 | Input switch closure 3.17 msec debounce filter |
| 4 | Input digital interrupt enabled, no debounce filter |
| 5 | Input switch closure interrupt enabled 3.17 msec, debounce filter |
| 6 | Undefined |
| 7 | Undefined |
| 8 | Undefined |
| 9 | No change |
Type: Constant