Attribute
A numeric code to determine what should happen to the file affected by the FileManage instruction. Attribute codes are a bit field. The codes are as follows:
Bit | Decimal | Description |
---|---|---|
bit 0 | 1 | Program not active |
bit 1 | 2 | Run on power up |
bit 2 | 4 | Run now |
bits 1 & 2 | 6 | Run now/Run on powerup |
bit 3 | 8 | Delete |
bit 4 | 16 | Delete all |
bit 5 | 32 | Hide |
Setting a file's attributes to Hide makes it inaccessible using communications or the keyboard, but it can still be set as Run Now or Run on Power Up.
A program marked as Run on Power Up can be disabled when power is first applied to the datalogger by pressing and holding the DEL key on the (optional) CR1000KD.
Type: Constant