Thermistor

A small stainless steel needle containing a thermistor extends from the middle of the four sonic transducers in the center of the anemometer.

The air temperature is taken using a unique design without solar radiation shielding. The ClimaVue 50 G2 calculates the air temperature accurately because solar radiation and the wind speed are known. These are the two main parameters that determine the bias between measured air temperature and the actual air temperature. The ClimaVue 50 G2 solve the energy balance and accurately estimates the actual air temperature based on the solar load of the body and the convective cooling of that temperature sensor.