Power requirements

Protection: Power inputs are protected against surge, over-voltage, over-current, and reverse power. IEC 61000-4 Class 4 level.

CHG Terminal Characteristics (CHG+ and CHG-) :

  • Input from Power converter or solar panel

  • *ES1 PS2 energy sources only

  • 16 to 32 VDC

  • Input current limit @ 12 VDC:

    • Hold limit 1.2 A @ 20 °C

Input voltage must be at least 0.3 V higher than the voltage required to charge the battery; 40 VDC sustained voltage limit without damage. Transient voltage suppressor (TVS) diodes at the BAT and CHG terminals clamp transients to 19 to 21 V and 19 to 40 V respectively. Sustained input voltages in excess of 19 V or 40 V respectively can damage the TVS diodes.

Battery Terminal Characteristics (BAT+ and BAT-):

  • Voltage input 12 VDC only
  • Hold Current limit 2.5 A @ 20 °C
NOTE:

*Energy Source Class 1 (ES1) and Power Source Class 2 (PS2), as defined in Clauses 5 and 7 of IEC/AS/NZS 62368-1:2022.

External Batteries:

  • Float charge on BAT terminal
  • 12 VDC
  • Valve-regulated, lead-acid (VRLA)
  • 2 to 24 Ah battery typical

Vehicle Power Connection: When primary power is pulled from the vehicle power system, a second power supply OR charge regulator may be required to overcome the voltage drop at vehicle start-up.

USB Device Power: Functions that will be active with USB Device 5 VDC include sending programs, adjusting data logger settings, and making some measurements. If USB Device is the only power source, then the CS I/O port and the 12V and SW12 terminals will not be operational. When powered by USB Device (no other power supplies connected) Status table field Battery = 0.

Internal Lithium Battery: 1/2AA, 1.2 Ah, 3.6 VDC (Tadiran L5902S) for battery-backed memory and clock. 1.5-year life with no external power source. See also Internal battery.

Average Current Drain:

Assumes 12 VDC on BAT terminals — add 2 mA if using CHG terminals.

  • Idle: <1 mA
  • Active 1 Hz Scan: 3 mA
  • Active 20 Hz Scan: 67 mA
  • Serial (RS-232/RS-485): Active + 25 mA
  • Ethernet Power Requirements:
    • Ethernet 1 Minute: Active + 1 mA
    • Ethernet Idle: Active + 4 mA
    • Ethernet Link: Active + 47 mA

Wi-Fi Additional Current Contribution at 12 VDC:

Mode

Wi-Fi Option

Client Mode 7 mA idle, 70 mA communicating
Access Point Mode 62 mA idle, 70 mA communicating
Sleep (use IPNetPower() or DevConfig setting to disable) <1 mA